TeSys D IEC contactor, 65 A, 3 P, 40 HP at 480 VAC, nonreversing, 120 VAC 50/60 Hz coil
SKU: LC1D65G7
Main
Range
TeSys
Range of Product
TeSys Deca
Product or Component Type
Contactor
Device short name
LC1D
Contactor application
Motor control
Resistive load
Utilisation category
AC-1
AC-2
AC-4
AC-3
poles description
3P
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz
[Ie] rated operational current
80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
65 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
[Uc] control circuit voltage
120 V AC 50/60 Hz
Complementary
Motor power kW
30 kW at 440 V AC 50/60 Hz (AC-3)
11 kW at 400 V AC 50/60 Hz (AC-4)
30 kW at 380...400 V AC 50/60 Hz (AC-3)
30 kW at 415 V AC 50/60 Hz (AC-3)
37 kW at 1000 V AC 50/60 Hz (AC-3)
37 kW at 500 V AC 50/60 Hz (AC-3)
37 kW at 660...690 V AC 50/60 Hz (AC-3)
18.5 kW at 220...230 V AC 50/60 Hz (AC-3)
Maximum Horse Power Rating
10 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to CSA
10 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to UL
20 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to CSA
20 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to UL
20 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to CSA
20 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to UL
5 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA
5 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL
50 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to CSA
50 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to UL
50 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to CSA
50 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to UL
Compatibility code
LC1D
Pole contact composition
3 NO
Protective cover
With
[Ith] conventional free air thermal current
10 A (at 140 °F (60 °C)) for control circuit
80 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity
140 A AC for control circuit conforming to IEC 60947-5-1
1000 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity
1000 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating
10 A gG for control circuit conforming to IEC 60947-5-1
125 A gG at <= 690 V coordination type 1 for power circuit
125 A gG at <= 690 V coordination type 2 for power circuit
Average impedance
1 mOhm - Ith 80 A 50 Hz for power circuit
Power dissipation per pole
6.4 W AC-1
[Ui] rated insulation voltage
Control circuit 600 V CSA
Control circuit 600 V UL
Power circuit 600 V CSA
Power circuit 600 V UL
Control circuit 690 V IEC 60947-1
Power circuit 690 V IEC 60947-1
Overvoltage category
III
[Uimp] rated impulse withstand voltage
8 kV IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
6000000 cycles
Control circuit type
AC 50/60 Hz
Coil technology
Without built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits
0.3...0.6 Uc 140 °F (60 °C) drop-out AC 50/60 Hz
0.8...1.1 Uc 140 °F (60 °C) operational AC 50 Hz
0.85...1.1 Uc 140 °F (60 °C) operational AC 60 Hz
Inrush power in VA
140 VA cos phi 0.75 (at 68 °F (20 °C))
160 VA cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA
13 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
15 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation
4…5 W at 50/60 Hz for control circuit
Operating time
12...26 ms closing
4...19 ms opening
Maximum operating rate
3600 cyc/h 140 °F (60 °C)
Connections - terminals
Control circuit: screw clamp terminal 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Control circuit: screw clamp terminal 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Control circuit: screw clamp terminal 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminal 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminal 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminal 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end
Power circuit: connector 1 0.004…0.05 in² (2.5…35 mm²) - cable stiffness: solid with cable end
Power circuit: connector 2 0.004…0.05 in² (2.5…35 mm²) - cable stiffness: solid with cable end
Power circuit: connector 1 0.004…0.05 in² (2.5…35 mm²) - cable stiffness: flexible without cable end
Power circuit: connector 2 0.004…0.04 in² (2.5…25 mm²) - cable stiffness: flexible without cable end
Power circuit: connector 1 0.004…0.05 in² (2.5…35 mm²) - cable stiffness: flexible with cable end
Power circuit: connector 2 0.004…0.05 in² (2.5…35 mm²) - cable stiffness: flexible with cable end
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminal flat Ø 6 mm
Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminal Philips No 2
Power circuit 44.3 lbf.in (5 N.m) screw clamp terminal flat Ø 6 mm
Power circuit 44.3 lbf.in (5 N.m) screw clamp terminal flat Ø 8 mm
auxiliary contact composition
1 NO + 1 NC
Auxiliary contacts type
Mirror contact 1 NC IEC 60947-4-1
Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Terminals description ISO n°1
(A1-A2)CO
(13-14)NO
(21-22)NC
Minimum switching voltage
17 V for control circuit
Minimum switching current
5 mA for control circuit
Insulation resistance
> 10 MOhm for control circuit
Non-overlap time
1.5 ms on de-energisation between NC and NO contacts
1.5 ms on energisation between NC and NO contacts
Mounting Support
Rail
Plate
Environment
Standards
EN 60947-5-1
CSA C22.2 No 14
EN 60947-4-1
UL 508
IEC 60947-4-1
IEC 60947-5-1
Product Certifications
CCC
UL
BV
CSA
LROS (pending)
GOST
RINA
GL
DNV
IP degree of protection
IP2X IEC 60529
IP2X VDE 0106
Climatic withstand
IACS E10 exposure to damp heat
Permissible ambient air temperature around the device
23…140 °F (-5…60 °C)
-40…158 °F (-40…70 °C) at Uc
Operating altitude
9842.52 ft (3000 m) without derating
Fire resistance
1562 °F (850 °C) IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Shocks contactor opened 10 Gn for 11 ms)
Shocks contactor closed 15 Gn for 11 ms)
Vibrations contactor opened 2 Gn, 5...300 Hz)
Vibrations contactor closed 4 Gn, 5...300 Hz)
Height
5 in (127 mm)
Width
3.0 in (75 mm)
Depth
4.7 in (119 mm)
Net Weight
3.09 lb(US) (1.4 kg)
Ordering and shipping details
Category
US10I1222357
Discount Schedule
0I12
GTIN
3389110436976
Returnability
Yes
Country of origin
CZ
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
5.512 in (14.000 cm)
Package 1 Width
5.315 in (13.500 cm)
Package 1 Length
3.740 in (9.500 cm)
Package 1 Weight
3.172 lb(US) (1.439 kg)
Unit Type of Package 2
S02
Number of Units in Package 2
5
Package 2 Height
5.906 in (15.000 cm)
Package 2 Width
11.811 in (30.000 cm)
Package 2 Length
15.748 in (40.000 cm)
Package 2 Weight
16.486 lb(US) (7.478 kg)
Unit Type of Package 3
P06
Number of Units in Package 3
80
Package 3 Height
29.528 in (75.000 cm)
Package 3 Width
23.622 in (60.000 cm)
Package 3 Length
31.496 in (80.000 cm)
Package 3 Weight
290.525 lb(US) (131.780 kg)
Contractual warranty
Warranty
18 months
Enter your zip code to see prices
Delivery of products may differ based on your Zip code

New modern look & feel of all machines
Designed to meet the requirements of industrial and HVAC applications
Easier to install and operate with multi-standard screws